Excluding the regions of Crimea, Donetsk and Luhansk
Petro-Canada™ Lubricants' distribution network extends to over 80 countries worldwide
Petro-Canada Lubricants ENVIRONTM Hydraulic Fluid S is a premium ashless environmentally acceptable lubricant that is compliant with 2013 US EPA Vessel General Permit (VGP) and Swedish Standard SS 155434, RISE SP listed. Its carefully selected biodegradable, minimally toxic and non-bioaccumulative chemistry makes it particularly suited for use in hydraulic systems operating in environmentally sensitive areas. ENVIRONTM Hydraulic Fluid S is designed for year-round use in both mobile and stationary hydraulic systems including those operating in low and high temperature extremes.
ENVIRONTM Hydraulic Fluid S is designed for use in both mobile and industrial hydraulic systems, particularly those operating in environmentally sensitive areas including marine, wetland, forestry, mining, construction and public utility operations.
ENVIRONTM Hydraulic Fluid S 32 and 46 are compliant with the following standards and specifications:
These fluids are suitable for use in equipment manufactured by Bosch Rexroth, Parker Denison, Danfoss, Oilgear, Hydreco, Dynex and others.
|
ENVIRONTM HYDRAULIC FLUID S |
|||
|---|---|---|---|
|
|
Test Method |
32 |
46 |
|
Start-up Temperature1, °C / °F |
- |
-40/-40 |
-34/-29 |
|
Operating Temperature1, °C / °F |
- |
-20 to 77 / -4 to 171 |
-13 to 91 / 9 to 196 |
|
Density, kg/L @ 15°C |
ASTM D4052 |
0.845 |
0.857 |
|
Kinematic Viscosity @ 40°C, cSt |
ASTM D445 |
30.62 |
46.18 |
|
Viscosity Index |
ASTM D2270 |
177 |
178 |
|
Pour Point, °C/°F |
ASTM D5950 |
-51 / -60 |
-48 / -54 |
|
Flash Point, COC, °C/°F |
ASTM D92 |
227 / 441 |
223 / 433 |
|
Water Separability @ 54°C / 129°F, |
ASTM D1401 |
40-40-0 (5) |
40-40-0 (10) |
|
Foam, Sequence I, ml/ml |
ASTM D892 |
10/0 |
10/0 |
|
Copper Corrosion, 3 h @ 100°C / 212°F |
ASTM D130 |
1a |
1a |
|
Rust Prevention, Procedures A & B, 24 h |
ASTM D665 |
Pass |
Pass |
|
Air Release @ 50°C / 122°F, minutes |
ASTM D3427 |
2.6 |
5.0 |
|
RPVOT, minutes |
ASTM D2272 |
1251 |
943 |
|
Oxidation Stability, hours - Dry |
ASTM D943M |
> 5500 |
> 5500 |
|
Four-Ball Wear Scar Diameter, mm |
ASTM D4172 |
0.40 |
0.40 |
|
FZG Failure Load Stage |
ASTM D5182 |
11 |
11 |
|
V104C Vane Pump Test |
ISO 20763 |
Pass |
Pass |
|
Hydrolytic Stability |
ASTM D2619 |
< 3.0 |
< 3.0 |
|
Elastomer Compatibility, NBR 2, 100°C, 168 h |
ISO 1817 |
Pass |
Pass |
The values quoted above are typical of normal production. They do not constitute a specification.
1 Operators should always refer to their equipment manufacturer’s recommendations regarding the operating temperature ranges and fluid viscosity requirements.
Petro-Canada Lubricants recommendations are approximate and based on the below:
- Start-up temperature is defined as the temperature at which the fluid dynamic viscosity is 10,000 cP.
- The lower limit of operating temperature range for both mobile and industrial machinery is defined as the temperature at which the fresh fluid dynamic viscosity is
750 cP. The upper limit of operating temperature range is defined as the temperature at which the after shear kinematic viscosity of the fluid is 10 cSt for mobile
equipment and 13 cSt for industrial equipment.